Limit switch SERIE MP720


 

 

A sealed position switch, with positive opening operation, dual breaking, with direct connection by cable moulded into the housing. The degree of safety sought on a machine often depends on the reliability of a switch, especially during an emergency shutdown.
The MP720 series provides this guarantee thanks to the switch’s positive opening operation and the rigid mechanical linkage between the controller and the contact bridge causing the breaker circuit to open.

 

Descriptions

 

 

Approval EN 947-5-1
Housing Glass fiber reinforced
Mechanism

Forced break

Slow action

Contact Fine Silver, Gold contact upon request
Circuit 1 NO + 1NC
Termination

Cable moulded 0.75 mm2

PVC -20°C to 70°C

PUR -40°C to 90°C

SI -40°C to 130°C

Actuator Variety of operation heads Stainless steel
   
Degree of protection

IP67

Power rating

AC-15 3A

DC-13 0.27A

Thermal current 6A
Dimensions 50 x 30 x 16 mm
   

Operating temperature range

-25°C to +70°C

(suited for -40°C to +130°C)

Mechanical life 10 x 106 cycles

 

 

Actuators

                     

 

DOMED PLUNGER
The actuator must be operated axially.
Vertical button operating speed >1mm/s.

 

Switching diagram
* = Positive opening operation travel (smp)

 

Man_positive1.JPG

 

In free position, a clearance of 0.5 to 1.0 mm has to be left from the top of the actuating button.
The plunger must not be used as a mechanical endstop.
Plunger actuators with a M12x1 male threaded collar must be secured by that collar using the nuts provided for that purpose.

 

 
 
Type 1G : Metal plunger    
MP720-1G.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (mm)
Positive openning operation position Pmp max. (mm)

4.0

10.0

20.5 ± 0.5

16.60

Type 1GA :  Metal plunger with nuts    
MP720-1GA.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (mm)
Positive openning operation position Pmp max. (mm)

4.0

10.0

35.0 ± 0.5

31.10

 

ROLLER PLUNGER
This may be operated by means of a rotating or sliding cam.
A cam the angles of which are in excess of 40° or the speed of which is in excess of 2m/s must not strike the roller plunger.
The contact point must be directly above the axis of the roller.

 

Switching diagram
* = Positive opening operation travel (smp)

Man_positive1.JPG


The strike angles and position must be so calculated as to avoid a violent shock to the roller ; the cam must be so shaped as to ease the roller back to the free position.

 

 
 
Type 1GLA :  Metal roller plunger    
MP720-1GL.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (mm)
Positive openning operation position Pmp max. (mm)

4.0

10.0

30.0 ± 0.5

26.10

Type 1GTA :  Metal roller plunger    
MP720-1GT.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (mm)
Positive openning operation position Pmp max. (mm)

4.0

10.0

30.0 ± 0.5

26.10

Type 1GALA/1GATA :  Metal longitudinal / transverse roller plunger with nuts    
MP720-1GAL.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (mm)
Positive openning operation position Pmp max. (mm)

4.0

10.0

47.0 ± 0.5

43.10

     

 

ROLLER LEVER 4G
The actuator 4G is recommended for rapid movements although sharp movements and shocks to the roller should be avoided.
The lever must be eased back to the free position.
Strike angle : 30°
Maximum speed: 5m/sec.

 

Switching diagram (4G..)
* = Positive opening operation travel (smp)

 

Man_positive2.JPG

Tableau_4gen.JPG

 

 

 
 
Type 4GXXP :  Lever with nylon roller    
MP720-4G.JPG Actuating force Fa max. (N)
Positive operating force Fmp min (N)
Free position Pr (°)
Positive openning operation position Pmp max. (°)

1.0

2.5

0

58

     
     

 

 Switching diagram

 

 Cable isolation Polyvinyl chloride  Polyurethane  Silicone
 Code in the reference of the article  PVC  PUR  SI
 Element of contact Za form Schema720PVCEn.JPG Schema720SIEn.JPG

 

 

Terminology - Samples applications

 

Pmp Positive opening operation position.
Actuator position at the point where the positive opening of the contacts is achieved.
Position of the actuator when the positive opening operation on the circuitbreaking contacts has been achieved.
Position in, which pre-determined dielectric voltage rating requirements is met between the open contacts in the switchable circuit.
smp Positive opening operation travel.
The minimum distance between the start of the movement of the actuator and the position where the positive opening of the contacts is achieved.
Distance between the rest position and the positive opening operation position.
Fmp Positive opening operation force.
The actuating force applied to the actuator to cause it to achieve the positive opening operation.
   

 

Sliding door (lateral movement)

In this case also the switch has to be operated as the door opens.
Care has to be taken to ensure that the positive opening operation switch remains in that position during the full open travel of the door.
Protective doors of this type are generally used on machines operating at high revolutions with cooling fluids. Consequently, it is essential in such applications that a switch with IP67 protection be used.

 

Porte_coulissante.JPG

 

Hinged door (rotating)

 

The problem with fitting a positive opening operation position switch to a hinged door is that the switch has to be operated as the door opens. Hence, the switch cannot be operated directly by the door but rather via a notched cam.

 

Porte_pivotante.JPG
   

 

 

Information commande
  MP72 0 - 0 -
1G / 4 2
PVC

Contact material

0: Silver contact

1: Gold contact

               

Actuator

1G: Metal plunger

1GA : Metal plunger with nuts

1GLA : Metal roller plunger

1GTA : Metal roller plunger

1GALA : Metal plunger longitudinal roller with nuts

1GATA : Metal plunger transverse roller with nuts

4GXXP : Lever with nylon roller

               
Number of wire

4 : 4 Wires section 0.75 mm2 / 19 AWG

               

Length of cable

1 : Length 1m

2 : Length 2m

4 : Length 4m

               

Cable material

PVC : Polyvinyl chloride

PUR : Polyurethane

SI : Silicone